Search

Home / INSTRUKART / Calibration
Precision universal calibrator/Universal Process loop Calibrator/Multifunction process calibrator - Measuring Current, Resistance, Voltage for Calibration of Process Control Instruments; Model: BTH-C9 in Kuwait Precision universal calibrator/Universal Process loop Calibrator/Multifunction process calibrator - Measuring Current, Resistance, Voltage for Calibration of Process Control Instruments; Model: BTH-C9 in Kuwait Precision universal calibrator/Universal Process loop Calibrator/Multifunction process calibrator - Measuring Current, Resistance, Voltage for Calibration of Process Control Instruments; Model: BTH-C9 in Kuwait Precision universal calibrator/Universal Process loop Calibrator/Multifunction process calibrator - Measuring Current, Resistance, Voltage for Calibration of Process Control Instruments; Model: BTH-C9 in Kuwait Precision universal calibrator/Universal Process loop Calibrator/Multifunction process calibrator - Measuring Current, Resistance, Voltage for Calibration of Process Control Instruments; Model: BTH-C9 in Kuwait Precision universal calibrator/Universal Process loop Calibrator/Multifunction process calibrator - Measuring Current, Resistance, Voltage for Calibration of Process Control Instruments; Model: BTH-C9 in Kuwait

Precision universal calibrator/Universal Process loop Calibrator/Multifunction process calibrator - Measuring Current, Resistance, Voltage for Calibration of Process Control Instruments; Model: BTH-C9

KWD 186.500

Brand
INSTRUKART
Category
Calibration
Weight
250 g
1 +

Special Features

  • Multifunction Calibrator | High Accuracy | High Stability | Measuring Current, Resistance, Voltage | Backlight LCD | Operating Temperature: 5°C to 50°C | Operating relative Humidity: <80% RH | Storage Temperature: -10°C to 55°C | Storage Humidity: <90% RH
  • DC Voltage Measurement: 4.000 V, 40.00 V, 400.0 V | Resolution: 0.001V, 0.01V, 0.1V | Accuracy: 0.2%+4 | DC mV Measurement: 40.00 mV, 400.0 mV | Resolution: 0.01mV,0.1mV | Accuracy: 0.5%+6 ,0.2%+4 | AC Voltage Measurement: 400.0 mV, 4.000V, 40.00V, 400.0V | Resolution: 0.1 mv, 0.001V, 0.01V, 0.1V | Accuracy: 1.0%+4, 0.5%+4, 0.5%+4, 0.5%+4
  • DC Current Measurement: 40.00mA, 400.0mA | Resolution: 0.01mA,0.1mA | Accuracy:0.2%+4 | AC Current Measurement: 40.00mA, 400.0mA | Resolution: 0.01mA,0.1mA | Accuracy:0.5%+4 | Resistance Measurement: 400.0 Ohms, 4.000KOhms, 40.00 KOhms, 400.0 KOhms, 4.000 MOhms, 40.00 MOhms
  • RTD Measurement: Pt100, Cu50 | Frequency Count: 50.00 Hz, 500.0 Hz, 5.000 KHz, 50.00 KHz, 100.0 Hz | Power Supply: 6V Batteries | Dimension: 205×95×42mm
  • Supply Scope: 1 Unit of BTH C9 Loop Power Calibrator, Instruction manual, 1 Protective cover, Silicon Leads | Applications: Process Control Instruments, Temperature & Pressure Transmitters.

Description

Portable calibrator designed to source and measure voltage (mV/V), current (mA), resistance (Ohm), thermocouples, RTDs, frequency, and pulse signals. Offers high accuracy (as low as ±0.2 %+4 counts), wide ranges for TC types R, S, K, E, J, T, N, B and RTD Pt100/Pt200/Pt500/Pt1000, dual display for simultaneous measurements, full IEC 61010 safety rating, and loop-power functionality. Ideal for field technicians calibrating transmitters, I/P converters, sensors, and control systems.

Related Items


{"error":"Error","cart_limit":"You have too many items in your cart.","prod_limit":"You cannot add any more of this item"}