Search

Home / Dwyer / Pressure & Vacuum
Dwyer MSX Magnesense Differential Pressure Transmitter, MSX-W20-IN-LCD, Wall Mount, Universal Current/Voltage Outputs, Bi-Directional, Range 0.1, 0.15, 0.25, 0.5" wc, LCD Display in Kuwait Dwyer MSX Magnesense Differential Pressure Transmitter, MSX-W20-IN-LCD, Wall Mount, Universal Current/Voltage Outputs, Bi-Directional, Range 0.1, 0.15, 0.25, 0.5" wc, LCD Display in Kuwait

Dwyer MSX Magnesense Differential Pressure Transmitter, MSX-W20-IN-LCD, Wall Mount, Universal Current/Voltage Outputs, Bi-Directional, Range 0.1, 0.15, 0.25, 0.5" wc, LCD Display

KWD 81

Brand
Dwyer
1 +

Special Features

  • Applications: Filter monitoring in air handler units; Building pressure in pharmaceutical/semiconductor clean rooms; Duct static pressure in commercial buildings; Air velocity/flow in VAV systems
  • Benefits/Features: Rotatable 180° display for ease of reading; UL94 V-0 and plenum ratings that add safety to a variety of applications
  • Service: Air and non-combustible,compatible gases; Accuracy: ±1% FSO; Stability: ±1% FSO/year; Temperature Limits: -4 to 158°F (-20 to 70°C).
  • Power Requirements: 10-36 VDC (2-wire), 17-36 VDC or isolated 21.6-33 VAC (3-wire); Output Signals: 4-20 mA (2-wire); 0-10 V or 0-5 V selectable (3-wire).
  • Response Time: Instantaneous (default) or 3 s (selectable); Zero and Span Adjustments: Digital push-button.

Description

The Series MSX Magnesense Differential Pressure Transmitter combines the stability and versatility of the original Series MS2 Magnesense II transmitter for use in building control applications. The MSX simplifies the ordering process to deliver the desired configuration, which reduces product setup time. Pressure ranges are available in Pa, mm w.c., and in w.c. All pressure ranges can be configured in unidirectional or bidirectional modes, providing a total of 32 ranges. The MSX transmitter can provide a linear pressure output or a linear velocity output with the square root extraction from the transmitter. Additional parameters have been included to expand the square root capability for calculating flow. Dual voltage and milliamp output signals can be used to provide both control and equipment output signal verification. ADDITIONAL SPECS: Loop Resistance: Current output: 0-1250 Ω max; Voltage output: min. load resistance 1 kΩ. Current Consumption: 21 mA max continuous. Electrical Connections: 4-wire removable European style terminal block for 16 to 26 AWG. Electrical Entry: 1/2˝ NPS thread. Display (optional): 4 digit LCD. Process Connections: 1/8˝, 3/16˝, 1/4˝, 5 mm, and 6 mm ID flexible tubing. Enclosure Rating: NEMA 4X (IP66), UL 2043 (Plenum), UL94 V-0. Mounting Orientation: Pressure sensor measurement unaffected by orientation. Weight: 8.0 oz (230 g). Agency Approvals: CE.

Related Items


{"error":"Error","cart_limit":"You have too many items in your cart.","prod_limit":"You cannot add any more of this item"}