Dry Block High Temperature Calibrators (Range: 50 to 650°C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs,Thermal Plants, Metallurgical Plants Model: AI-DBC-02 in Kuwait Dry Block High Temperature Calibrators (Range: 50 to 650°C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs,Thermal Plants, Metallurgical Plants Model: AI-DBC-02 in Kuwait Dry Block High Temperature Calibrators (Range: 50 to 650°C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs,Thermal Plants, Metallurgical Plants Model: AI-DBC-02 in Kuwait Dry Block High Temperature Calibrators (Range: 50 to 650°C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs,Thermal Plants, Metallurgical Plants Model: AI-DBC-02 in Kuwait Dry Block High Temperature Calibrators (Range: 50 to 650°C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs,Thermal Plants, Metallurgical Plants Model: AI-DBC-02 in Kuwait Dry Block High Temperature Calibrators (Range: 50 to 650°C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs,Thermal Plants, Metallurgical Plants Model: AI-DBC-02 in Kuwait

Dry Block High Temperature Calibrators (Range: 50 to 650°C) with Thermocouples (T, J, K, N, R, S) for Calibration Labs,Thermal Plants, Metallurgical Plants Model: AI-DBC-02

KWD 443

Category
Calibration
1 +

Special Features

  • Dry Block Temperature Calibrator Range: 50 to 650°C | Accuracy: ±0.6°C | Bath Stability: ±0.05°C | Stabilization Time: 20 Min. | Heating Time: 30 to 32 Min. (50 to 650°C) | Resolution: 0.1°C | Units: °C / °F Switchable | Display: Graphical with LED Backlight | Power Supply: 230V AC ± 5% / 50Hz,1.2 KW for 650DBC
  • Transmitter Supply: 24V DC ± 10% (Loop Powered) |Block Diameter: 25.4 mm | Block Depth: 120 mm | Insertion Tube Depth: 110 mm | Temperature Setting: Digital Display through feather touch keypad | Display Stability: ±0.2°C | Radial uniformity Fixed Steps for: ±0.3°C with similar probes | Switch Test: Continuity check with OPEN / CLOSE indication
  • Measuring Parameters: mA, mV, Volts, Ohms, RTD3 (Pt 100)3 | mA Range: 0 to 25 mA; Resolution: 0.001 mA; Accuracy: ±0.025% of Reading + 10 µA | mV Range: 0 to 1000.0 mV; Resolution: 0.01 mV; Accuracy: ±0.025% of Reading + 0.25 mV | Volts Range: 0 to 10.000 V; Resolution: 0.001 V; Accuracy: ±0.025% of Reading + 3 mV | Ohms Range: 0 to 400 Ohms; Resolution: 0.01 Ohms; Accuracy: ±0.025% of Reading + 0.1 Ohm | RTD3 Range: -200 to 8500 C; Resolution: 0.10 C; Accuracy: ±0.025% of Reading + 0.30 C
  • Thermocouple Types: T, J, K, N, R, S | Thermocouple Range( T,J,K,R,S): -200 to 400°C; Resolution: 0.1°C; Accuracy: ±0.025 % of Reading + 1°C |Thermocouple Range(R,S): 300 to 1760°C; Resolution: 1°C; Accuracy: ±0.025 % of Reading + 1°C
  • dry block temperature calibrator rtd thermocouple tabletop liquid bath simulator calibration labs plants metallurgical pharmaceutical divisions thermal plants high probe 650 degree celsius calibrador de temperatura de bloque seco
  • dry block temperature calibrator rtd thermocouple tabletop liquid bath simulator calibration labs plants metallurgical pharmaceutical divisions thermal plants high probe 650 degree celsius calibrador de temperatura de bloque seco

Related Items