1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12* twisted pair-wire terminated with a 0.1 & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start Turning ON/OFF the power supply very quickly may lead to increase of the set up
time.
7.The 150% peak load capabilty is built in for up to 1 second for 12-48V.LRS-350 will enter hiccup mode if the peak load is delivered
for over 1 second and wil recover once it resumes to the rated current level(115VAC/230VAC).
8. The ambient temperature derating of 50 /1000m is needed for operating altitude greater than 2000m(6500ft).
9. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply
Exception:
Power supplies used within the following end-devices do not need to fulfill EN61000-3-2
a) professional equipment with a total rated input power greater than 1000W:
b) symmetrically controlled heating elements with a rated power less than or equal to 200W