Technical data
SENSING INPUT
voltage:180-277vac,three phase
frequency:50-60 HZ nominal
POWER INPUT
voltage:180-260vac max
output
voltage:max63v at 220v ac input
current :continuous 7A
regulation:+/-1.0%
Description
Detect Input:voltage 220/440VAC 10% single phase
Frequency: 50/60HZ with jumper settings
Power input voltage: 180-260VAC single-phase two-wire
Frequency: 50/60HZ
Maximum output voltage: 63VDC
Continuous current 7A, non-15A continuously for 15 seconds
Minimum 6 ohm resistor 105 ohm maximum
DROOP CT input: 5A
The maximum sensitivity corresponding to 4% drop PF0.7 2A maximum input 5A
Stability of each degree temperature difference changes, voltage drift of 0.05%
When using an external voltage adjustment potentiometer 1K Ohms 1 Watt of 10%
Voltage adjustment range of 180-277VAC @ 220V 360-554VAC @ 440V
Built-in EMI filter EMI suppression
Maximum power consumption 20Watt
Turning point for the low-frequency protection 60HZ 45HZ 55HZ 50HZ turning point
OVEREXCITATION automatically turn off automatically turns off the excitation voltage exceeds 65 2VDC by the delay after